Thermal camera checking a ceiling during ADI’s Warwick investigation
ADI’s published photograph from the investigation described here.

The problem

A kitchen ceiling patch and water moving down a wall prompted an ADI investigation in Warwick. More than one pipe route was possible.

How the source was confirmed

Moisture mapping, thermal imaging and a camera inspection helped direct the investigation. A pressure test had limitations because a shower mixer could not be isolated. With agreed access through the boiler-cupboard floor, the engineer observed drips from a condensate elbow onto the pipe below.

The outcome and its limits

Affected condensate and hot-water pipe sections were replaced. The hot-water repair remained dry during a one-hour observation. The report also recommended correcting the condensate pipe’s fall because retained silted water suggested an ongoing risk.

This is a summary of ADI’s published account, not evidence that the ceiling had dried or been redecorated. The practical lesson is to test the suspected route and confirm the source before repairing the visible finish.